SCULLY – OVERFILL AND GROUND

OVERFILL AND GROUND


Ground Plug & CableGround Plug & Cable

DESCRIPTION

The control monitor connects to a heavy duty Sculcon®  junction box with attached cable and special quick release snap-on plug. The Scully Ground Plug connects to a specially designed electronic Scully Ground Ball mounted on each vehicle. The controller in conjunction with the ground ball provides and veries vehicle grounding before loading can begin. The controller must receive an electronic return signal from the ground ball throughout the loading operation.

ORDERING INFORMATION

Plug & Cable Assembly w/Sculcon Series Junction Box

For Safe and Reliable Rack to Vehicle Connection

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

Scully plugs are made of heavy duty molded polyurethane with stainless steel contacts. The fuel resistant cables are available in 30′ coiled or 20′ straight styles. Scully plugs and cables are the product of years of industry experience and offer durable, efcient operation. They are designed for use only with the intrinsically safe output circuits of Scully’s ST-35, ST-15 and Intellitrol®.

Scully Plugs and Cables are used to connect the Scully loading rack control monitor to the vehicle mounted socket. The plugs and cables are the pathway for the control unit/sensor signals which monitor the status of overll prevention, electro-static grounding and vehicle identication during loading operations.

Sculcon Junction Box with Cable Assembly

FEATURES AND BENEFITS

  • Extremely rugged design which can withstand harsh environments and mishandling.
  • Non-removable socket locator pins fitted directly into the plug housing.
  • Permanent socket locator pins that won’t loosen or back out.
  • Internal cable retention clamp to prevent cable pull-out or twisting.
  • Molded glass-reinforced, polycarbonate contact block with positive locator keyways for easy disassembly and or reassembly.
  • Molded arrow on plug housing for easy visual alignment with socket.
  • Stainless steel electrical contact, spring loaded to insure proper contact with the truck socket pins.
  • Virtually indestructible polyurethane plug shell, color coded to match Scully truck sockets.
  • Compression strain relief spring prevents the cable from bending or crimping.
  • Heavy-duty petroleum resistant cable with higher visibility and cold weather exibility.
  • Plug & Cable Assembly w/Sculcon Series Junction Box

For Safe and Reliable Rack to Vehicle Connection

Plug and Cable Assemblies

For Safe and Reliable Rack to Vehicle ConnectionGround Plug & Cable- description

TECHNICAL SPECIFICATIONS

  • Environmental Temperature: –40°F to +140°F (-40°C to +60°C)
  • 10 Conductor Cable: White– 16 Guage / All Other– 18 Guage / Straight– 20 feet (6m) /Coiled– 30 feet (9m)

The cables working length is enclosed in a fuel-resistant jacket. The cable is oil and gas resistant. Other lengths are available upon request.

  • Materials: Plug Body: Polyurethane / Insulator: Polycarbonate / Contact Pins: / Stainless Steel /Junction Box: Aluminum
  • Approvals: These devices are part of an intrinsically safe system certied by FM.

ORDERING INFORMATIONGround Plug & Cable-informat

PDF
Ground-Plug-and-Cable

ST-15

ST-15Single Point Overfill Prevention Controller

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

The Scully single point overll prevention controllers feature two-wire optic or thermistor sensing. They are mounted at a loading rack or ll station for connection to a single compartment tank vehicle.

The ST-15 provides the vehicle with an adequate static ground path to the rack provided the vehicle overll equipment is wired and maintained to factory specications. For additional ground proving options, the system works in conjunction with the Scully Groundhog Self-Proving Ground Verication System.

FEATURES AND BENEFITS

  • Maximum safety with Dynacheck® automatic and continuous self-checking circuitry.
  • Will not permit loading under any fault or wet sensor conditions.
  • Signals for automatic shut-off of product ow within a half-second of detecting an overfill condition.
  • Ideal overfill prevention for refuelers, rail tank cars, tank trucks, chemical trailers and other one compartment vehicles.
  • 30 years of proven, dependable performance.
  • Easy connection to vehicles with versatile high impact plug and cable units.
  • Approved by Factory Mutual

Technical Diagram of Model ST-15 ELKTechnical Diagram of Model ST-15 ELK

Single Point Overfill Prevention Controller

TECHNICAL SPECIFICATIONS

  • FM & CSA Approved Versions of: Thermistor Sensors SP-BL, SP-BLU, SP-BLH / Two-wire Optic Sensors SP-TO, SP-TOM, SP-IO, SP-IR, SP-TO(SS), SP-TO(SS)HP
  • Enclosures: Explosion-proof, weathertight. Corrosion inhibiting epoxy paint optional
  • Indicator Lamps: Red = Power On/Non-Permit / Green = Permit
  • Approvals: XP-AIS / I / 1 / CD / T6 Ta = -40°C to 60°C; Entity – 61654; XP-AIS/ I / 1 / IIB/ T6 Ta = -40°C to 60°C; Entity 61654 / Class I Zone 1 Group IIB
  • Turn on response time: 6 – 30 seconds (typical) for thermistors. Two-wire optics turn on instantly.
  • Shutdown Response Time: 0.5 seconds maximum
  • Power Requirements: 105 – 130 VAC, 50-60 Hz, 20 watts maximum, 210 – 250 VAC nominal, 50-60 Hz, 20 Watts maximum
  • Connections: Provided by internal terminal strips
  • Output Control: One normally open volt free contact, rated 250 VAC, 5A resistive, energized when the sensor is dry.
  • Output Control Fuse: Internal 5 Amperes.
  • Size: Refer to Diagram for EL & ELK models.
  • Weight: 28 lbs. (12.7 kg) EL & ELK Units

NOTE: The Scully ST-15 is an intrinsically safe system. For maximum safety, it should be used only in conjunction with sensors manufactured by Scully not to jeopardize the conditions of the approvals.

ORDERING INFORMATION

PDF
ST15

ST-15-WX Series

ST-15-WX 4Overfill Prevention Control Units for Storage Tanks

Multiple-Point Liquid-Level Detection System for High and Low Level Warning and Spill Prevention.
Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

The Scully ST-15-WX series multiple point liquid level detection control units are available in two through twelve channel models. The ST-15-WX is commonly used to provide overfill protection, high level warning, low level warning and/or pump and valve control functions. They are well suited for multiple fixed storage tank and transport tank applications where individual display and/or output control is required.

The output control function may be reversed to alarm for a dry sensor condition rather than a wet sensor condition for low level warning.

The ST-15-WX enclosure includes individual red indicator lamps that light when a sensor is wetted, a power indicator lamp, an alarm acknowledge push button and alarm test push button. Once a sensor alarm is acknowledged the alarm output circuit is reset, however, the indicator lamp remains lit until the sensor is dry again.

ST-15-WX series controllers incorporate Scully’s unique and exclusive Dynacheck circuitry when connected to Scully sensors. Using pulsed signals to simulate a wet or “unsafe” condition, the monitor automatically and continuously checks the entire system operation; controller, wiring, connectors and sensors for faults thirty (30) times per second.

If liquid comes in contact with the sensor tip, or in the unlikely event a fault occurs, the pulsed signals cease and the monitor signals an audible alarm and/or controls, pumps and valves for immediate shutdown.

Compatible liquid level sensors for the The ST-15-WX employ solid state thermistor and Instant-On optic sensing technology. Sensors and holders constructed of aluminum or stainless steel for sensing a wide variety of liquid products including petroleum and chemicals are available. Consult the technical data sheets listed on the back for further sensor information.ST-15-WX-all-dimensions

FEATURES AND BENEFITS

  • Incorporates Dynamic Self-Checking™ circuitry which monitors the controller, wiring, connections and sensors for faults thirty times per second.
  • Signals an audible alarm and/or controls pumps and valves for automatic shutdown.
  • Monitors from 2 –12 total sensing points depending on model
  • Provides liquid level detection for a wide variety of petroleum and chemical products.
  • Uses output sensors approved as intrinsically safe for use in Class 1, Division 1, Group D hazardous environments
  • Features NEMA 4 style watertight housings.
  • Works in conjunction with either Scully eld-proven thermistor or Instant-On optic sensors.

Multiple-Point Liquid-Level Detection System for High and Low Level Warning and Spill Prevention.

TECHNICAL SPECIFICATIONS

  • Product Range: Gasoline through #6 oil, waste oil, chemicals, water, etc. Consult Scully for specific application questions.
  • Controls: Alarm test push button*. Alarm silence circuit with push button and automatic reset.
  • Indicator Lights: Green= Power On; Red= Alarm Condition
  • Response Time: High-Level: .05 seconds maximum / Low-Level: 3-7 seconds.
  • Enclosure: NEMA 4 style for indoor/outdoor use.
  • Power Requirements: 115 VAC, +/- 15%, 50–60HZ, 20 watts maximum. Also available in 240 VAC models, consult Scully for details.
  • Electrical Connections: Internal Terminal Strips.
  • Output Provisions: External Alarm, 115VAC, 3 A max. Individual channel SPDT contacts, rated 5A-250 VAC.
  • Compatible Sensors: Refer to technical data sheets; 60635, 60715.
  • Chemical Applications: Refer to technical data sheet 67100

Unit must be located outside hazardous areas. Please contact our Customer Service Applications Department for a customized quotation for your specific application.

*Alarm test push button not available on ST-15-WX2

ORDERING INFORMATIONST-15-WX ORDERING INFORMATION

PDF
ST15WX

ST–35

ST–35Multiple Point Optic Sensing Overfill Prevention Controller

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

The Scully overfill prevention system interfaces with optic sensors. It is typically usedfor bottom and top-loading of tank vehicles. It is mounted at the loading rack/gantry and connects to the vehicle via the Scully plug and cable assembly. The attached plug and 30’ coiled cable connect to the vehicle mounted receptacle, or socket, which is wired to the refueler sensor. Please consult Scully for alternate plug and socket styles to prevent mixing AV gas and jet fuels in dedicated refuelers. The ST-35 system provides the vehicle with an adequate static ground path to the rack/gantry provided the vehicle’s overfill equipment is wired and maintained to factory specifications. For additional ground/earth verification options, consult Scully for information on the Groundhog Self-Proving Grounding System.

FEATURES AND BENEFITS

  • Maximum safety with Dynacheck® automatic and continuous self-checking circuitry.
  • Will not permit loading under any fault or wet sensor condition.
  • Signals for automatic shut off of product ow within a half-second of detecting a potential overfill condition.
  • Complete compatibility with Scully IntelliCheck® and Load Anywhere® onboard systems and independent five-wire optic sensors.
  • Easy connection to vehicles with rugged, versa-tile plug and cable units.
  • ST-35 models monitor 1 – 8 compartment tank vehicles while the ST-35C models monitor 1 – 12  compartment tank vehicles.
  • Approved by Factory Mutual (FM)

Technical Diagram of Model ST-35 ELKTechnical Diagram of Model ST-35 ELK

Multiple Point Optic Sensing Overfill Prevention Controller

TECHNICAL SPECIFICATIONS

  • Temperature Range: -40° to +140° F (-40° to +60° C)
  • Weight: 28 lbs. (12.7 kgs.)
  • Response Time: 0.5 seconds maximum
  • Approvals: ST-35: FM for use in Class 1, Division 1, Group D hazardous locations.
  • Power Requirements: 100–130 VAC, 50/60 Hz, 20 W max. 200–250 VAC, 50/60 Hz, 20 W max.
  • Connections: Provided by internal terminal strips
  • Output Relay: One normally open volt-free contact, rated 250 VAC 5A resistive. Energized when the sensors are dry.
  • Output Control Fuse: Internal 5 Ampere
  • Housing Options: Consult Scully for optional epoxy painted housings for corrosive atmospheres.

NOTE: For maximum safety, use only in conjunction with sensors manufactured by Scully to not jeopardize the conditions of these approvals.

ORDERING INFORMATIONRDERING INFORMATION-ST35

PDF
ST35

ST–47 Groundhog

ST–47Vehicle Static Grounding System

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

Don’t let unsure grounding methods leave you guessing. Transport vehicles should be properly tied to ground before and during the loading operation. There should never be any doubt that the grounding systems at your terminals are performing their proper function. Many systems give you little assurance of their operation. The Scully Groundhog gives you complete assurance that a proper static ground tie-in is present.

The Groundhog is a self-proving grounding system for maximum safety in loading operations. It can operate in conjunction with your existing Scully Overll Prevention System or as an independent unit.

Scully Signal Company has over 30 years of electronic liquid handling experience providing the ultimate dependability, service and safety.

The Scully Groundhog grounding system can be used for a wide variety of loading applications for use with tank trucks, rail cars, and aircraft refuelers.

FEATURES AND BENEFITS

  • Self-Proving, the Groundhog continuously monitors the grounding connection throughout the loading operation.
  • Can be used in conjunction with your Scully Overll Prevention System offering one quick connection for overll protection and grounding verication.
  • Can also be used as a completely independent grounding system with a special quick-release plug for grounding to a specially designed, vehicle mounted, electronic ball.
  • Direct earthing tie point at loading rack available.
  • Immediately shuts down the loading operation if proper static grounding is not present.
  • FM approved
  • No manual checks are needed.

IMPORTANT

Static grounding is used to dissipate any static charges which can build up as a result of product ow or other movement. Some applications such as rail lines and pipelines may also have stray currents present. In these situations the rail or pipeline must be bonded to ground independently from the Scully system. Local codes should be consulted regarding wire gauges and number of conductors.

Scully Ground BoltScully Ground Bolt

THE SCULLY GROUNDHOG PROVES IT

The Scully Groundhog gives you complete assurance that grounding to the vehicle’s frame has been accomplished. The Groundhog is an intelligent system which continuously and automatically monitors the grounding connection during the entire loading operation.

The Groundhog is designed to immediately shut down the loading operation if the earth tie-in is broken. That’s proof-positive, something no other system can provide.

The Groundhog control monitor is mounted at the loading rack.Indicator lights on the face of the control monitor are visual proof that proper grounding has been accomplished.

The Groundhog requires that each vehicle be equipped with a specially designed Scully electronic ground ball or bolt. Before the loading operation can begin, the controller must see an intelligent return signal from the ground ball or bolt, indicating that a proper grounding connection has been made.

ARE YOUR GROUNDING SYSTEM OPTIONS LIMITED?

The Groundhog Control Unit can be wired into your existing Scully Overfill Prevention System for the ultimate safety system. Just one connection gives you overfill and grounding protection. This single connection simplies loading and eliminates the need for additional plugs and cables at the loading rack.

The Groundhog utilizes a separate conductor in the existing Scully Overfill Prevention Plug and Cable together with a special Scully Ground Bolt mounted on each vehicle. The Scully Ground Bolt’s sensing lead is wired to the Scully Overfill Prevention Socket.

Only Scully offers you a complete, integrated overfill prevention and vehicle grounding system for maximum safety in your loading operations.

CONTROL UNITS AND PLUG AND CABLE ASSEMBLY

If you intend to wire the Groundhog in conjunction with your existing Scully Overfill Prevention System, you need only order the control monitor. For the independent system, order the control monitor and junction box with plug and cable.

ORDERING INFORMATIONORDERING INFORMATION-st47

Scully Groundhog Control Monitor with Plug and CableVehicle Static Grounding System

DON’T USE A SYSTEM THAT IS EASILY CHEATED

There are many systems that claim to be foolproof and even self-checking. It is possible with many of these systems to bypass a safe earth tie-in by attaching the clamp to the rack, a metal shim or by jumping the plug contacts with a paper clip. In many cases, there is no proof that proper earthing has been made or that the system is functioning correctly.

The Scully Groundhog when used together with a Scully Ground Ball or Ground Bolt, foils these typical cheating methods and malfunctions that can lead to grounding vehicles improperly.

The Scully Grounding System ensures that unless the proper grounding connection has been made, the loading process will not begin. It will automatically shut down the loading operation if the ground is broken. The Groundhog’s intelligent monitoring capabilities and the special electronic circuitry inside the Scully Ground Ball and Ground Bolt form a self-proving system. No manual checks are needed.

Only the Scully Groundhog can provide you with the safest and most dependable means for vehicle static grounding. It maintains the integrity of your loading operation.

SCULLY HAS A SYSTEM FOR EVERY APPLICATION

The Groundhog can be used as a completely independent system. This system is ideal for top loading or applications where a Scully Overll Prevention System is not in use.

The control monitor connects to a heavy duty Sculcon® junction box with attached cable and special quick release snap-on plug. The Scully Ground Plug connects to a specially designed electronic Scully Ground Ball mounted on each vehicle. The controller in conjunction with the ground ball provides and verifies vehicle grounding before loading can begin. The controller must receive an electronic return signal from the ground ball throughout the loading operation.REPLACEMENT PARTS-st47All Dimensions-ST47

TECHNICAL SPECIFICATIONS

  • Operation Temperature: -40° to +140° F (-40° to +60° C)
  • Enclosure: Explosion – Proof Weather – Proof Housing.
  • Indicators: Red−not grounded/non-permit. Green−grounded/permit.
  • Response Time: 0.5 seconds maximum.
  • Electrical Connections: Internal terminal strips, identified for easy installation.
  • Bypass Switch: Key lockable off-on bypass switch for ELK model only.
  • Output Control: One normally open user contact rated 250, 5A resistive load.

Power Requirements:

  • ST-47–115 Models: 105–125 VAC, 50/60 Hz. 0.250 Amperes maxim
  • ST-47–240 Models: 208–240 VAC, 50/60 Hz. 0.125 Amperes maximum.

Shipping Weights:

  • ST-47 ELK; 26 lbs (12 kgs)
  • ST-47 EL; 26 lbs (12 kgs)
  • SC-47; 9 lbs (4 kgs)

Approvals: Explosion-proof with intrinsically safe ground connection outputs. Rated for Class I, Division 1, Groups C & D Hazardous (Classified) Locations, by FM Global (FM) to Canadian and United States standards.

PDF
ST47-Groundhog

Intellitrol®2

Overfill Prevention, Ground Verification & Vehicle Identification for Petroleum & Chemical Gantries

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

The Intellitrol®2 is intended to serve as a secondary overfill protection system for loading operations. It is intended for use in hazardous locations and is packaged in an explosion-proof (ameproof) enclosure and has both International and US approvals and certifications.

The Intellitrol®2 performs a variety of monitoring functions and provides a number of outputs to control valves, pumps and other systems including Terminal Automation Systems (TAS). It has an integrated display to indicate system and monitoring status, a bypass capability, and communications for integration with TAS and other systems.

The Intellitrol®2 contains a pair of microprocessors, each with its own relay, that monitors critical functions. Only when both processors detect a safe condition will both relays close and make outputs permissive.

The Intellitrol®2 is designed to be Faylsafe® and in the event of a failure (power, sensors, or internal electronics) the unit will enter a non-permissive (safe) state.

This state-of-the-art Dynamic Self-Testing® system controller provides overfill prevention, vehicle ground verification and vehicle identification operating in a single enclosure. The Intellitrol®2 also provides the user with comprehensive diagnostic information, both locally on the exterior of the control unit housing and remotely to the terminal automation system via RS-485 communications.

FEATURES & BENEFITS

  •  Overfill prevention, ground verification and vehicle identification in one compact state of the art explosion-proof enclosure.
  •  Scully Dynacheck® automatic and continuous self-checking circuitry.
  •  Automatic detection of two-wire optic/thermistor or five-wire optic vehicle sensors.
  • Monitoring of up to 8 two-wire or 15 five-wire vehicle sensors.
  • Complete visual diagnostic display of overfill sensors’ status. Will not permit loading under any fault or wet sensor condition.
  •  When used with Scully Sensors, the Scully Intellitrol®2 Control Unit has been certified as part of a SIL 2 Overfill Prevention System.
  • Easy connection to vehicles with rugged high impact industry standard plug and cable units.

TECHNICAL SPECIFICATIONS

Temperature Range:

• Operating: ICC Models: -40° to +60°C (-40° to +140°F)

  • Storage: -45° to +85°C (-50° to +185°F)

Power Requirements: 100 – 130 VAC (120 VAC Setting) or 200 – 250 VAC (240 VAC Setting) 50/60 Hz, 30 watts maximum

Enclosure: Explosion-proof weathertight housing with powder coated corrosion resistant finish. Weathertight rating: Type 4X and IP 65.

Sensor Inputs: Up to 8 Scully two-wire optic/thermistor sensors (6 or 8 channels) or 15 ve-wire optic sensors (maximum). Automatic detection of two-wire vs. ve-wire sensors. 3-wire high-temperature thermistor sensors is not supported.

Ground Verifiation Inputs: When congured for Ground Bolt detection, a Scully Ground Bolt connected to pin number 9 of the overll prevention system socket(s) and installed onto the vehicle frame per Scully installation instructions (No.61081) is needed to satisfy this input. When congured for Resistive Ground detection, all vehicles must be wired with socket pin number 9 and 10 connected to separate points on the vehicle chassis.

Dead Man Input: An intrinsically safe input is provided for an optional dead man switch.

Outputs: Two independent outputs are provided as follows:

• Main Permissive Output: A Form-A (“normally open”) AC relay output with “monitored redundant contacts”. This output closes when all overll prevention sensors are dry and functional, a proper ground connection, and/or vehicle I.D. (optional), and/or deadman (optional) is established. This output is an AC control output and must only be used with AC voltage. This output should be used for product ow shutdown capability and is rated at 250 VAC, 5 amps resistive.

  • Main Form-C, Volt-Free Output Relay: A Form-C (“normally open” and “normally closed”) volt-free redundant relay output contact.These output contacts reverse state (“normally open” closes and “normally closed” opens) when all overll prevention sensors are dry and functional, and a proper ground connection, and/or deadman (optional), and/or vehicle I.D. is established. If a volt-free relay output contact is needed, the “normally open” relay output contact may be used for product ow shut down. The “normally closed” relay output contact is intended for any additional non-critical output status reporting functions. This Form-C contact is rated at 250 VAC, 5 amps resistive.

Response Time: 450 milliseconds maximum after wet sensor or fault condition.

Communications Port: The communications port is a half-duplex, RS-485 multi-drop communications port, utilizing Modbus™ RTU (straight binary) communications protocol at 1200, 2400, 4800, 9600 or 19200 baud rate; 8 bits; even, odd or no parity.

Approvals: All Intellitrol2 units fall under the approvals for:

  • • FM Approved for use in Canada and the United States Rated: Class I, Division 1, Groups C and D, T4, 4X; with Intrinsically Safe outputs for connection to Class I, Division 1, Group C and D, and Class I, Ta = -40°C to +60°C
  • • NEMA 4X rating, for either indoor or outdoor use and is Watertight, dust tight and corrosion resistant.
  • • ATEX: – Ex d ia IIB T4 IP65 (Tamb = -40oC to +50oC) Gb
  • • IECEx Certication: GBBASExTR11.030500
  • Intellitrol2 Control Module & Display Board
  • Intellitrol2 ICC Control Module
  • Intellitrol2 ICC-SIL Control Module

Dimensions: Refer to diagram

Shipping Weight: 14.1 kg. (31 lbs.)MODEL DESIGNATIONS intellitrol2

PDF

PDF
Intellitrol2

Ground Verication Clamp and Cable Unit

Model SC-47CC:CLMPFor use with Sculcon Junction Box, Model SC-47CC/CLMP

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

The Scully SC-47CC/CLMP Clamp and Cable Unit is designed to drain static charges built up on vehicles, railcars and other metal liquid tank containers. The clamp unit is designed to be connected, via two wires, to the Scully Groundhog™ grounding verification system. When the clamp is attached to bare metal on the tank container, the system utilizes an intrinsically safe signal to verify that a proper static bond exists during liquid transfer operations.*

Static grounding is used to dissipate any static charges which can build up as a result of product ow or other movement. Some applications such as rail lines and pipelines may also have stray currents present. In these situations the rail or pipeline must be bonded to ground independently from the Scully system. Local codes should be consulted regarding wire gauges and number of conductors.

If the clamp is not properly attached to the tank vehicle, the system will not allow product to transfer. If at any time during the transfer process the clamp is disconnected, the system will send a signal to stop the product transfer.

The clamp and cable unit is connected to a heavy duty, weatherproof junction box. The junction box acts as a housing to connect the cable wires and the controller wiring. In the event of a drive-away, the cable pulls out of the junction box. This maintains vapor tight safety and prevents damage at the control monitor. Other systems without a junction box disconnect and may allow non-intrinsically safe signals within the liquid transfer environment during a drive-away accident.

FEATURES AND BENEFITS

  • Verification of static grounding when properly connected to the trailer frame.
  • Intrinsically safe operation.
  • Spring-loaded clamp jaws with adjustable contact pins for a solid bond to the trailer frame.
  • Heavy-duty, weather-sealed aluminum junction box to house cable wiring.
  • The clamp and cable disconnects from the junction box during a drive-away accident, preventing damage to the control monitor and maintaining intrinsic safety.

*WARNING

When used in conjunction with a Scully Groundhog, the clamp provides a resistance (non self-proving) verication system. Thus, attaching the clamp to a metallic object or to a vehicle, which already has a return path to ground, could give a permissive indication through this alternate path, which may not include the vehicle. To ensure self proving operation, the vehicle must be equipped with a Groundbolt or Groundball.Model SC-47CC:CLMP-2

TECHNICAL SPECIFICATIONS

  • Junction Box: Weather-sealed die-cast aluminum box. Stainless steel external hardware.
  • Clamp: Aluminum alloy, corrosion resistant. Stainless steel contact points.
  • Cable: Oil resistant, Philaprene 2-Jacketed / Coiled: 32′ (extended) (10 meter) / Straight: 20′ (6 meter)
  • Cable Strain Relief: Stainless Steel
  • Clamp Strain Relief: Stainless Steel

SC-47CC-info order

PDF
Ground-Clamp-Cable

Plug & Cable Assembly w/Sculcon Series Junction Box

For Safe and Reliable Rack to Vehicle Connection

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

Scully plugs are made of heavy duty molded polyurethane with stainless steel contacts. The fuel resistant cables are available in 30′ coiled or 20′ straight styles. Scully plugs and cables are the product of years of industry experience and offer durable, efficient operation.They are designed for use only with the intrinsically safe output circuits of Scully’s ST-35, ST-15 and Intellitrol®.Scully Plugs and Cables are used to connect the Scully loading rack control monitor to the vehicle mounted socket.The plugs and cables are the pathway for the control unit/sensor signals which monitor the status of overfill prevention,electro-static grounding and vehicleidentication during loading operations.

FEATURES AND BENEFITS

  • Extremely rugged design which can withstand harsh environments and mishandling.
  • Non-removable socket locator pins fitted directly into the plug housing.
  • Permanent socket locator pins that won’t loosen or back out.
  • Internal cable retention clamp to prevent cable pull-out or twisting.
  • Molded glass-reinforced, polycarbonate contact block with positive locator keyways for easy disassembly and/or reassembly.
  • Molded arrow on plug housing for easy visual alignment with socket.
  • Stainless steel electrical contact, spring loaded to insure proper contact with the truck socket pins.
  • Virtually indestructible polyurethane plug shell, color coded to match Scully truck sockets.
  • Compression strain relief spring prevents the cable from bending or crimping.
  • Heavy-duty petroleum resistant cablewith higher visibility and cold weather flexibility.

For Safe and Reliable Rack to Vehicle Connection

TECHNICAL SPECIFICATIONS

Environmental Temperature: -40°F to +140°F (-40°C to +60°C)

10 Conductor Cable:

    • White– 16 Guage
    • All Other– 18 Guage
    • Straight– 20 feet (6m)
    • Coiled– 30 feet (9m)

The cables working length is enclosed in a fuel-resistant jacket. The cable is oil and gas resistant. Other lengths are available upon request.

Materials:

    • Plug Body: Polyurethane
    • Insulator: Polycarbonate
    • Contact Pins: Stainless Steel
    • Junction Box: Aluminum

Approvals: These devices are part of an intrinsically

PDF
Plug-Cable-Sculcon

Comments are closed.